The 9760 Change Parts constrain an aerosol
can as it is being pressurized from the inside.
The 9760 consists of a cage fixture, with fitted
top and bottom inserts, that quick-clamps
around a can before the can is mounted in the
tester.
The top insert is machined to fit the can neck,
while the bottom insert is molded to fit the
bottom of the samples to be tested. These
inserts are mounted on rings which are held
together with threaded connecting rods and the
bottom ring slides via an adjustable clamp. The
sample is placed inside the cage and the clamp
is then closed, securing the sample between
the top and bottom inserts.
Ordering
The 9760 is ordered by specifying 9760 and
supplying several samples to Altek. Samples
MUST be provided to ensure proper manufacture
of the 9760 Change Parts.